Parámetros del sistema RO
The first-pass RO system uses KC-BW-ZM8040 membrane elements and is arranged in a 12:6 matriz de dos etapas. Each pressure vessel is loaded with 6 membrane elements, for a total of 108 elements.
The system is designed at approximately 18.0 LMH, with a recovery rate of about 75%. Operating pressure is typically 0.85–1.05 MPa, and overall system salt rejection is maintained at ≥99.4%. The first-pass RO permeate capacity is about 72 m³/h, with product water conductivity typically controlled at <8 μS/cm.